Direct Burial Wirecable

Wirenco 8/3 UF-B Wire, Underground Feeder and Direct Earth Burial Cable 50Ft


Wirenco 8/3 UF-B Wire, Underground Feeder and Direct Earth Burial Cable 50Ft
Wirenco 8/3 UF-B Wire, Underground Feeder and Direct Earth Burial Cable 50Ft
Wirenco 8/3 UF-B Wire, Underground Feeder and Direct Earth Burial Cable 50Ft
Wirenco 8/3 UF-B Wire, Underground Feeder and Direct Earth Burial Cable 50Ft

Wirenco 8/3 UF-B Wire, Underground Feeder and Direct Earth Burial Cable 50Ft   Wirenco 8/3 UF-B Wire, Underground Feeder and Direct Earth Burial Cable 50Ft

Wirenco 8/3 UF-B Wire, Underground Feeder and Direct Earth Burial Cable (50Ft Cut). Size: 50Ft Cut Brand: wirenco MPN: 37956-# UPC: 850026183559 EAN: 0850026183559. Number of Cable Strands: Multi Strand. 16 x 15 x 4.5 inches; 17.4 Pounds.

Best Sellers Rank: #308,043 in Tools & Home Improvement (See Top 100 in Tools & Home Improvement) #1,452 in Electrical Wire. #1,452 in Electrical Wire. Customer Reviews: 4.5 4.5 out of 5 stars 22 ratings. #8 AWG Wire with Annealed (Soft) Copper (Cu) Conductors. Used Indoor for Wet or Corrosive Locations, Resistant to Light and Moisture. Used Outdoor for Direct Earth Burial, Resistant to Sunlight and Moisture. Has a Heat Capacity of 90 Degrees Celcius and is Rated for 600-Volts, Has an Allowable Ampacity of 40 Amps.

Color of Wire May not be the Same as the Picture Shown. Applications: UF-B is an underground feeder and branch circuit wiring cable.

It can be used as an underground feeder from an existing building to outdoor lighting fixtures, pumps, outbuildings and other equipment. Its applications are outlined in Article 340 NEC 2008 and NEC 2011. UF-B is rated at 600 volts. Although it is rated at a conductor temperature of 90ºC dry / wet, its ampacity is limited to 60ºC according to the NEC 2008 AND NEC 2011.

UF-B may be directly buried or installed where exposed to sunlight. When used as an NM cable it must comply with the requirements in NEC 2008 and NEC 2011 Article 334. Standards: ASTM - B3 and B-8 UL Standard 83 UL Standard 493 Federal Specification A-A-59544 National Electrical Code, NFPA 70, 2011 Edition RoHS/REACHConstrction: Insulation: Polyvinyl Chloride (PVC) with a nylon covering.

Jacket:Sunlight and moisture resistant gray PVC. Specifications: Size:8 AWG Number of Conductors:3 PVC Insulation Thickness:0.035 inches Ground Wire Size:8 AWG Nylon Thickness:0.005 inches Nominal Cable Dimensions:1.059 inches x 0.319 inches Weight per Foot: 0.304 lbs Allowable Ampacity: 40 Amps.

Your receive the wrong item.
Wirenco 8/3 UF-B Wire, Underground Feeder and Direct Earth Burial Cable 50Ft   Wirenco 8/3 UF-B Wire, Underground Feeder and Direct Earth Burial Cable 50Ft