6/2 UF-B Wire, Underground Feeder and Direct Earth Burial Cable (100 FT Cut). Applications: Type UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90°C (with ampacity limited to that for 60°C conductors) as specified by the National Electrical Code.
UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Standards: ASTM - B3 and B-8 UL Standard 83 UL Standard 493 Federal Specification A-A-59544 National Electrical Code, NFPA 70, 2011 Edition RoHS/REACHConstrction: Insulation: Polyvinyl Chloride (PVC) with a nylon covering.
Jacket:Sunlight and moisture resistant gray PVC. Specifications: Size:6 AWG Number of Conductors:2 PVC Insulation Thickness:0.035 inches Ground Wire Size:10 AWG Nylon Thickness:0.005 inches Nominal Cable Dimensions:0.73 inches x 0.338 inches Weight per Foot: 0.303 lbs Allowable Ampacity: 55 Amps. 100% Polyvinyl Chloride (PVC) with nylon covering.
#6 AWG Wire with Annealed (Soft) Copper (Cu) Conductors. Used Indoor for Wet or Corrosive Locations, Resistant to Light and Moisture. Used Outdoor for Direct Earth Burial, Resistant to Sunlight and Moisture. Has a Heat Capacity of 90 Degrees Celcius and is Rated for 600-Volts, Has an Allowable Ampacity of 55 Amps. Color of Wire May not be the Same as the Picture Shown.
Number of Cable Strands: Multi Strand. Date First Available: January 3, 2018. Except on weekend or public holidays. We stand behind our products. Your receive the wrong item.